激情午夜_午夜影院_午夜电影_午夜剧场_午夜电影院_神马午夜影院_神马午夜小电影_国产成人AV_成人精品视频99在线观看免费_国产精品国产成人麻豆app

您好,歡迎來到歐亞貿(mào)易網(wǎng)!請 |免費注冊

產(chǎn)品展廳本站服務(wù)收藏該商鋪

CHANGSHA LANGSHUO TECHNOLOGY CO LTD

免費會員
手機(jī)逛
CHANGSHA LANGSHUO TECHNOLOGY CO LTD
當(dāng)前位置:CHANGSHA LANGSHUO TECHNOLOGY CO LTD>>Alloy XFR Analyzer,Rohs Spectrometer>> Paes RoHS tester | RoHS2.0 adjacent benzene detector

Paes RoHS tester | RoHS2.0 adjacent benzene detector

產(chǎn)品二維碼
參  考  價:面議
具體成交價以合同協(xié)議為準(zhǔn)
  • 產(chǎn)品型號:
  • 品牌:
  • 產(chǎn)品類別:元素分析儀器
  • 所在地:
  • 信息完整度:
  • 樣本:
  • 更新時間:2025-07-15 09:06:31
  • 瀏覽次數(shù):3
收藏
舉報

聯(lián)系我時,請告知來自 歐亞貿(mào)易網(wǎng)

CHANGSHA LANGSHUO TECHNOLOGY CO LTD

其他

  • 經(jīng)營模式:其他
  • 商鋪產(chǎn)品:911條
  • 所在地區(qū):
  • 注冊時間:2025-07-13
  • 最近登錄:2025-07-13
  • 聯(lián)系人:
產(chǎn)品簡介

RoHS2

詳情介紹

RoHS2.0 adjacent benzene detector

RoHS phthalic tester RoHS2.0 phthalic detector Micro crack release phthalic tester
On June 4, 2015, the Official Gazette of the European Union (OJ) issued the Amendment Directive (EU) 2005/863 of RoHS2.0, which added 4 phthalates to the list of restricted substances of RoHS2.0 on the basis of the original 6 substances of RoHS (lead, cadmium, mercury, hexvalent chromium, polybrominated biphenyls and polybrominated diphenyl ethers). Thus, RoHS2.0 has 10 controlled substances.

According to RoHS2.0 testing standards, production enterprises need to purchase relevant equipment for rapid screening of raw materials, material self-inspection, internal quality control, customer factory inspection, etc. (Equipment required for conventional configuration: GCMS+EDXRF spectrometer), but the purchase of these equipment at the rate of millions, many enterprises are feeling great pressure, and enterprises have to do screening of raw materials, if not screening, product production will be buried a huge hidden danger, enterprises can not control whether their products meet the standards; According to the two pain points of the importance of internal screening and the huge investment needed to purchase equipment, Golden Valley Science Instrument has developed a set of new solutions specifically for the rapid screening needs of the four phthalines in Rohs2.0:
TP20-GC micro crack release aphenol rapid screening solution.

TP30PLUS has the following advantages:

Short sample making time: 20 minutes/sample making time * Rapid screening needs of enterprise users;

No waste gas and liquid waste: this does not need reagent, no pre-treatment, no waste gas and liquid waste;

Low procurement cost: PY+GCMS procurement cost is 1.2 million yuan, TP20-GC procurement cost is less than 300,000 yuan;

Low cost: no pre-treatment, no reagents and consumables, a year of use cost less than 5000 yuan;

Direct injection: direct solid or liquid injection without pre-treatment, good reproducibility, avoid human error;

Built-in standard curve: more intuitive judgment whether the material phthalic overstandard

No need for professional laboratory environment: only need ordinary operation space with air conditioning power can be installed and used.

Each component name and retention time

nameabbreviationRetention timeTime window band
Diisobutyl phthalateDIBP8.5240.05
Dibutyl phthalateDBP9.0410.05
Butyl benzyl phthalateBBP10.9410.05
Dioctyl phthalateDEHP11.9490.05

Results and discussion:
Standard curve and linear range (detection limit)

DIBP standard solutions with concentrations of 50ppm, 100ppm, 250ppm, 500ppm and 1000ppm were configured. The concentration was taken as the horizontal coordinate and the peak area of quantitative components was taken as the vertical coordinate. The standard curve and the linear correlation coefficient were shown below.

The table below shows the comparison of peak height and peak area of 5 standard samples with different concentrations:

Concentration (ppm)Peak height (pA)Peak area (A)
502038.78472.5
1002829.612607.7
2505720.624674.0
50012090.853037.4
100024747.2120759.3

The low detection limit of each component calculated by multiple signal-to-noise ratio is 25ppm

Repeatability (precision test)

Repeatability was determined at concentrations with low detection limits and the results are shown below.

RSD%
DIBPPeak heightPeak area
1944.83484.2
21007.33638.8
3903.23167.9
41205.64227.6
RSD%=12.24

Conclusion: The low detection limit of Rohs2.0 was 25 ppm (Shimazu PY+GCMS low detection limit was 50ppm), the linear correlation coefficient was greater than 0.998, RSDS %=12.24, * the requirements of enterprise material screening.

RoHS phthalic tester RoHS2.0 phthalic detector Micro crack release phthalic tester
The fourth part, in line with IEC62321-8 regulations and requirements
The four phthalines in the middle of Rohs2.0 are plasticizers, which are difficult to volatilize and need to be volatilized at high temperature (200oC-450oC). PY/TD-GC-MS (pyrolysis/thermal desorption – gas chromatography-mass spectrometry detector) is used as the current IEC standard. And we use TP20-GC micro-crack release technology (pyrolysis/thermal desorption – gas chromatographic spectrometer), specific analysis of what is the same and different:

1. PY/TD-GC-MS, approved by IEC, is a thermal pyrolysis + thermal desorption + gas chromatography + mass spectrometry detector, in which the pyrolysis temperature is up to 1200 degrees, and many large molecular substances are decomposed into small molecular substances, which will cause interference and false positive results, and MS mass spectrometry is needed for qualitative analysis.

2, TP20-GC is defined as a rapid screening system for phthalates, we only need to do 4 kinds of phthalates quantitative, so we set the heating range at 200oC-450oC this interval, so that the 4 phthalates are volatilized into the GC (gas chromatographic spectrometer) quantitative, and will not affect the results of other macromolecular substances cracking.

To sum up: then why our method does not have a mass spectrum detector? Because our positioning is to do the screening of 4 kinds of phthalines, and the temperature range we use is only 200oC-450oC, no other new substances interference, no qualitative detection, so TP20-GC does not need a mass spectrum detector.

RoHS phthalic tester RoHS2.0 phthalic detector Micro crack release phthalic tester
Experimental case 1, a headphone manufacturer in Shenzhen to OEM headphone plastic shell raw materials screening

1. A domestic brand gas Chromatograph (FID+SPI+ capillary column)

2, TP20 micro crack release accessory device processing equipment

3. Chromatographic column

4. A batch of other experimental equipment

Injection method: direct solid injection;

Detection items: To detect whether the original PVC green particles Rohs4 phthalines exceed the standardPaes RoHS tester | RoHS2.0 adjacent benzene detector Paes RoHS tester | RoHS2.0 adjacent benzene detector

上一篇: Paper Abrasion Wear Testers
下一篇: PGH-300/500 Hydrogen gas generator f
同類優(yōu)質(zhì)產(chǎn)品

在線詢價

X

已經(jīng)是會員?點擊這里 [登錄] 直接獲取聯(lián)系方式

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
亚洲无AV在线中文字幕| 亚洲日韩一区二区| 亚洲欧美在线观看| 迷人的人妻HHD语中字| 国产99久一区二区三区A片| 在线制服丝袜区|